                        商品の詳細:
                                                     
                
 
  | 
                    
| 機械試験報告書: | 提供された | 外容器素材: | 炭素鋼 | 
|---|---|---|---|
| 露点: | -65℃ | 外容器の直径: | 2000 mm | 
| 窒素出力: | ≤250Nm3/hr | 生産率: | 100〜10000nm3/h | 
| 消費電力: | 0.5~1.5kW/Nm3 | 空気圧縮機の電源: | 22-110KW | 
| 電源: | 380V/50Hz | 寿命: | +10年 | 
| 酸素出力: | ≤500Nm3/hr | 使用法: | 酸素 | 
| 内部素材: | ステンレス鋼 | テスト圧力: | 0.8MPA-1.6MPA | 
| ハイライト: | 93%±2% Purity VPSA Oxygen Generator,600m2 VPSA Oxygen Generator,0.5-1.5 kW/Nm3 Power Consumption Oxygen Generator | 
					||
| Model | O₂ Flow (Nm³/h) | O₂ Purity (±2%) | O₂ Pressure (MPa) | Air Consumption (Nm³/h) | Adsorption Form | 
|---|---|---|---|---|---|
| VPSA-3 | 3 | 93% | 0.2 | 0.6 | Normal Pressure Adsorption | 
| VPSA-6 | 6 | 93% | 0.2 | 1.2 | Normal Pressure Adsorption | 
| VPSA-10 | 10 | 93% | 0.2 | 2 | Normal Pressure Adsorption | 
| VPSA-20 | 20 | 93% | 0.2 | 4 | Normal Pressure Adsorption | 
| VPSA-30 | 30 | 93% | 0.2 | 6 | Vacuum Adsorption | 
| VPSA-50 | 50 | 93% | 0.2 | 10 | Vacuum Adsorption | 
| VPSA-80 | 80 | 93% | 0.2 | 16 | Vacuum Adsorption | 
| VPSA-100 | 100 | 93% | 0.2 | 20 | Vacuum Adsorption | 
| VPSA-150 | 150 | 93% | 0.2 | 30 | Vacuum Adsorption | 
| VPSA-200 | 200 | 93% | 0.2 | 40 | Vacuum Adsorption | 
| System Name | Content | Parameter | 
|---|---|---|
| Vacuum pump sealing water | Flow | 3m³/Hr | 
| Temperature | <32ºC | |
| Water quality (soft water) | <30mg/L (CaO), suspended matter: 5mg/L, pH value: 6~9 | |
| Pressure | >0.2Mpa sent to the water inlet of water equipment | |
| Vacuum pump cooling water | Flow | 4m³/Hr | 
| Temperature | <32ºC | |
| Water quality (soft water) | <560mg/L (CaO), PH value: 6~9 | |
| Pressure | >0.3Mpa sent to the water inlet of water equipment | |
| Oxygen compressor cooling water | Flow | Air-cooled | 
| Instrument air for butterfly valve | Quality | Dry, clean instrument air or inert gas | 
| Flow | 180m³/Hr | |
| Dew point temperature | -40ºC | |
| Dust particle size | Not more than 0.3μm | |
| Pressure | 0.4~0.7Mpa sent to the air bag (sub-cylinder) | |
| Power requirements | Voltage | 380V | 
| Installed capacity | 539KW sent to the equipment receiving cabinet | |
| Civil plant | The project is designed outdoors without the client providing a factory building. | |
| Equipment basis | Construction according to drawing requirements | |
コンタクトパーソン: Mrs. Kelly
電話番号: +86 15824687445