VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction

大画像 :  VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction

商品の詳細:
起源の場所: 中国
ブランド名: GNEE
証明: SGS
お支払配送条件:
最小注文数量: ≥1セット
価格: According to the product
パッケージの詳細: 木製のボックスパッケージ
支払条件: MoneyGram、Western Union、T/T、D/P、L/C、D/A

VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction

説明
名前: VPSAの酸素の発電機 寿命: +10年
消費: 省エネ 配置方法: 垂直
材料: 炭素鋼/ステンレス鋼 キーワード: VPSA酸素プラント
酸素出口圧力: 0.2-0.4 MPa 純度: 90-95%
状態: 新しい 機械テストレポート: 提供された
内部素材: ステンレス鋼 頻度: 50Hz/60Hz
動作圧力: 0.1-0.5 MPa 出力圧力: 10-15KAPまたはユーザーの要件として
ハイライト:

0.2-0.4 MPa Outlet Pressure VPSA Oxygen Generator

,

Vertical Placement Oxygen Production Equipment

,

Carbon Steel/Stainless Steel PSA Oxygen Generator

VPSA Oxygen Generator Energy-saving Competitive for Fish Farm
Product Description
Utilizing pressure swing adsorption technology with zeolite molecular sieve as the adsorbent, this system achieves nitrogen-oxygen separation. The molecular sieve selectively adsorbs nitrogen while oxygen enriches in the gas phase. The system employs a dual-tower process where one tower adsorbs oxygen while the other regenerates under negative pressure. PLC-controlled pneumatic valves alternate between towers for continuous, high-quality oxygen production.
Product Parameters
O2 Output (Nm³/h) 50 80 180 260 350 550 750 1200
O2 Purity (%O2) ≥99.6 ≥99.6 ≥99.6 ≥99.6 ≥99.6 ≥99.6 ≥99.6 ≥99.6
N2 Output (Nm³/h) 50 160 300 500 700 1000 1500 2000
N2 Purity (PPM O2) ≤10 ≤10 ≤10 ≤10 ≤10 ≤10 ≤10 ≤10
Liquid Argon Output (Nm³/h) - - - - - - - 30
Liquid Argon Purity (PPM O2 + PPM N2) - - - - - - - ≤1.5ppmO2 + 4ppmN2
Liquid Argon Pressure (MPa.A) - - - - - - - 0.2
Consumption (Kwh/Nm³ O2) ≤1.3 ≤0.85 ≤0.68 ≤0.68 ≤0.65 ≤0.65 ≤0.63 ≤0.55
Occupied Area (m³) 145 150 160 180 250 420 450 800
VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction 0 VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction 1 VPSA Oxygen Generator with 0.2-0.4 MPa Outlet Pressure Vertical Placement Carbon Steel/Stainless Steel Construction 2
Key Features
  • High-performance pneumatic valves with high-frequency cylinders and imported Metso positioners
  • SMC Solenoid valves and quick-opening valves with lifespan exceeding 3 million cycles
  • PLC intelligent program controller for easy operation and stable performance
  • Patented air flow distribution system for enhanced adsorption efficiency
  • Airbag-type clamping device prevents molecular sieve powdering
  • Original blizzard-style filling method ensures uniform distribution
  • Energy efficient with power consumption as low as 0.28KWh per cubic meter of pure oxygen
Installation Solution
The complete system includes screw type air compressor, nitrogen booster, air buffer tank, refrigerated dryer, filtration equipment, nitrogen buffer tank, nitrogen generator, nitrogen regulator, and filling manifold.
Step 1: Connect A&B from air compressor flange to refrigerated dryer flange using black DN50 high pressure tube
Step 2: Connect C&D from nitrogen generator to nitrogen booster using black DN50 high pressure tube
Step 3: Connect F from nitrogen booster to filling manifold using black DN50 high pressure tube
Step 4: Connect filling manifold to nitrogen cylinders
Installation Notes
  • Ensure all connections between equipment are properly sealed
  • Tighten all gaskets and screws securely
  • Prevent any air leakage during operation
Packing & Delivery
Equipment is packed with wooden cases, anti-collision foam blocks, and stretch film according to export standards. Two sets can be delivered in 20ft or 40ft containers. Boosters and fittings are packed in wooden cases with exterior signage and anti-collision protection. Fragile components like gauges, flowmeters, and controllers receive special protective packaging.
We also produce PSA Oxygen Generators, storage tanks, heat exchangers and related products. For inquiries about VPSA Oxygen Systems or other products, please contact us at info@gneeheatex.com.